The difference between a $300 pipe repair and a $3,000 drywall-and-remediation job is often just whether the leak was found before or after excessive wall opening. Our detection service in Tualatin uses the same methods utilities and insurance adjusters rely on โ to pinpoint the failure before anything is cut.

A pressure test tells us a leak exists. Detection equipment tells us precisely where.
Pressurized supply line leaks create a low-frequency sound as water escapes the pipe and contacts surrounding soil or structure. Our amplified listening devices filter background noise so we can triangulate the loudest point โ often to within 6โ12 inches of the actual break, through concrete slabs or behind drywall.
Active water leaks create temperature differentials on the surfaces they contact. An infrared camera shows these as color-coded heat maps, revealing the wet zone inside a wall or under a floor without any cutting. A cold water leak behind drywall appears as a spreading cool zone; a hot water leak shows the inverse.
Pressure decay testing is the standard by which we confirm a leak is present before committing detection equipment time. A rapid drop vs. a slow one also indicates the approximate size of the escape point.
For leaks that don't produce sufficient acoustic signature โ very slow leaks, polyethylene pipe, or leaks deep under concrete โ we introduce a nitrogen/hydrogen tracer gas mixture into the isolated pipe and use a calibrated gas detector at the surface to find where the gas escapes. Sensitive to concentrations far below what produces an audible acoustic signal.
Our detection service covers the full property, not just the obvious locations.
Thermal imaging supplements acoustic detection for slab leaks, identifying the thermal anomaly that appears on the floor surface as water migrates through the concrete.

We document the thermal anomaly, mark the approximate pipe location, and recommend a minimal access cut rather than a wide wall opening โ typically saving hundreds in drywall repair costs.
We also perform leak correlation surveys for longer line runs, using two listening points to triangulate the failure location mathematically.
Irrigation system leaks in main supply and lateral runs are found by isolating zones with the irrigation controller and pressure-testing each zone individually. Zone-by-zone testing narrows the failure to the smallest possible section.

We format detection reports specifically for insurance submission and provide documentation on our detection equipment and methodology to claims adjusters on request.
Commercial water loss from undetected leaks often shows up as elevated utility bills for months before physical evidence appears. We can assess a commercial building's plumbing system for suspected leaks at the property owner's or manager's request.
Finding a hidden leak isn't a single step โ it's a protocol that combines water loss confirmation, zone isolation, and targeted detection in sequence.
This step confirms we're looking for a real leak rather than a meter error or normal appliance cycling.
Zone isolation turns "there's a leak somewhere in the house" into "the leak is on the hot side supply between the water heater and the master bath."
Within the isolated zone, we deploy thermal imaging first โ scanning walls, floors, and ceilings for moisture anomalies. Then acoustic equipment confirms the specific pipe location and narrows it to the tightest possible point. Tracer gas is added if acoustic results aren't conclusive.
You receive a written detection report including pressure test results, detection method summary, leak location relative to fixed reference points, and thermal imagery. If you want us to repair the leak, we quote immediately and can execute same-visit.

My water bill doubled over three months. Masters Plumbing Service confirmed the meter was moving with everything off, isolated the cold supply to the kitchen as the failing branch, and used the acoustic device on the slab to pinpoint a location 4 feet from the outside wall under the kitchen floor. The repair crew opened a 10-inch circle in the tile, found a pinhole copper elbow exactly where detection said it would be. I was genuinely amazed at the precision.
Ceiling stain in the living room kept coming back despite two drywall patches. Masters Plumbing Service ran the thermal camera and found the wet zone was traveling from a supply line joint 9 feet away, flowing down a horizontal framing member โ explaining why the patch kept failing. They marked the actual pipe location, we opened 8 inches of wall there, and the repair held. No more stain.
Commercial building with elevated water costs for six months. Masters Plumbing Service ran zone-by-zone pressure isolation across four floors, narrowed the loss to the third-floor kitchen supply branch, and located the failure with thermal imaging at a concealed valve body in the ceiling. No damage to the finished ceiling.
Our detection technicians are equipped with acoustic, thermal, and tracer gas tools for the full range of leak scenarios found in Tualatin, OR homes and commercial properties.

Call now to schedule โ most detection appointments available within 24โ48 hours.
๐ Call +1-844-833-0201 Now